Plus 2.X:Other Parameters: Unterschied zwischen den Versionen
Aus Wufiwiki
Zur Navigation springenZur Suche springen
Krizzl (Diskussion | Beiträge) (Die Seite wurde neu angelegt: To start the calculation the initial conditions have to be defined. So check the initial room conditions (temperature, relative humidity, CO2 concentration) for the res...) |
Krizzl (Diskussion | Beiträge) Keine Bearbeitungszusammenfassung |
||
(Eine dazwischenliegende Version desselben Benutzers wird nicht angezeigt) | |||
Zeile 1: | Zeile 1: | ||
To start the calculation the initial conditions have to be defined. | To start the calculation the initial conditions have to be defined. | ||
The accuracy of the calculation can be established. Note, that lower accuracy also means faster calculation and likewise higher accuracy slower calculation. | *Check the initial room conditions (temperature, relative humidity, CO2 concentration) for the respective zone and modify them according to your needs. | ||
Besides it can be decided whether calculation should be aborted or continued with increased air supply from outer air if an negative air balance occurs. | *Next you can decide whether the distribution of solar gains should be proportional to area or user defined. If you choose user defined you can enter a solar gain value for each component of the zone under [[Plus 2.X:Visualized_Components#Thermal|Surface]] in the Thermal subsection. | ||
*Also a factor for solar radiation that goes directly to the inner air can be entered here. | |||
*The accuracy of the calculation can be established. Note, that lower accuracy also means faster calculation and likewise higher accuracy slower calculation. | |||
*Besides it can be decided whether calculation should be aborted or continued with increased air supply from outer air if an negative air balance occurs. | |||
<br> | <br> | ||
[[Bild:P2-otherparameters.png]] | [[Bild:P2-otherparameters.png]] |
Aktuelle Version vom 1. Juni 2011, 08:06 Uhr
To start the calculation the initial conditions have to be defined.
- Check the initial room conditions (temperature, relative humidity, CO2 concentration) for the respective zone and modify them according to your needs.
- Next you can decide whether the distribution of solar gains should be proportional to area or user defined. If you choose user defined you can enter a solar gain value for each component of the zone under Surface in the Thermal subsection.
- Also a factor for solar radiation that goes directly to the inner air can be entered here.
- The accuracy of the calculation can be established. Note, that lower accuracy also means faster calculation and likewise higher accuracy slower calculation.
- Besides it can be decided whether calculation should be aborted or continued with increased air supply from outer air if an negative air balance occurs.