Plus:SummaryPreparingACalculation: Unterschied zwischen den Versionen
Aus Wufiwiki
Zur Navigation springenZur Suche springen
Tes (Diskussion | Beiträge) (Die Seite wurde neu angelegt: Overview of the steps that have to be taken before starting a calculation: * First your can enter some optional information about project and case * Then you may sele...) |
Tes (Diskussion | Beiträge) Keine Bearbeitungszusammenfassung |
||
Zeile 1: | Zeile 1: | ||
Overview of the steps that have to be taken before starting a calculation: | Overview of the steps that have to be taken before starting a calculation: | ||
* First your can enter some optional information about project and case | * First your can enter some optional information about [[Plus:Dialog Project | project]] and [[Plus:Dialog Case | case]] | ||
* Then you may select the location of the to calculate project | * Then you may select the location of the to calculate project for a specific [[Plus:Dialog Climate | climate file]]. Further you can define some [[Plus:Dialog Climate | optional climate]] | ||
* You have to edit the building wither with the | * You have to edit the building wither with the [[Plus:DialogBuildingWizard#Automatic building wizard | automatic building wizard]] or a [[Plus:DialogBuildingWizard#Automatic building wizard | script file]]. Edit measures, shape and orientation | ||
* You may assign assemblies to the components of the building | * You may assign assemblies to the components of the building |
Version vom 8. Juli 2009, 10:24 Uhr
Overview of the steps that have to be taken before starting a calculation:
- Then you may select the location of the to calculate project for a specific climate file. Further you can define some optional climate
- You have to edit the building wither with the automatic building wizard or a script file. Edit measures, shape and orientation
- You may assign assemblies to the components of the building
- If needed fit in windows in the components and assign the window type
- You have to specify the inner climate with defining the temperatures, the relative humdities, the CO2 concentrations and the ventilation
- You may qoute the loads from accupancy or additional
- Then enter the equipment data about heating, cooling and ventilation system
- Now other parametrs like the initial room conditions or the accuracy of calculation have to be set
- At least the attached zones have to be specified
- When all inputs are done and the State of input data shows green, the calulation can be started