Depending on which building type is chosen, this section offers different input options. If a residential building is simulated in WUFI, only common household appliances and lighting have to be defined.<br>
For non-residential buildings, kitchen and office appliances as well as the occupancy has to be defined and attached to a utilization pattern.
== Residential building ==
== Residential building ==
[[Bild:Passive-innerloads.png|Inner Loads|right]]<br>
[[Bild:Passive-innerloads.png|Inner Loads|right]]<br>
Zeile 9: Zeile 11:


== Non-residential building ==
== Non-residential building ==
=== Utilization pattern ===
[[Bild:Passive-innerloads_nonres_utipattern.png|thumb|right|Utilization pattern]]
The mandatory data for utilization patterns is given over the columns of the table. The additional data is useful, depending on where the pattern is attached.
<br style="clear:both" />
=== Occupancy ===
[[Bild:Passive-innerloads_nonres_occupancy.png|right|thumb|Occupancy]]
Here you can define how many occupants your building has as well as additional humidity sources. When it comes to the activity of the occupants, WUFI can differ between children, sitting adults and standing adults. It is also possible to define the pattern for these people as well the quantity of people following this pattern. <br>
The additional data section contains a value about additional heat losses through evaporation and toilet settings.<br>
WUFI can use default values for a school if you are building one.

Version vom 2. Juli 2013, 09:14 Uhr

Depending on which building type is chosen, this section offers different input options. If a residential building is simulated in WUFI, only common household appliances and lighting have to be defined.
For non-residential buildings, kitchen and office appliances as well as the occupancy has to be defined and attached to a utilization pattern.

Residential building

Inner Loads


In this section electric devices and humidity sources are defined. They are important to estimate the energy and water demand, as well as the humidity load inside the building.

In the device scope, there are already a lot of common household devices, like dishwater etc. Device scope
For each device, the quantity and the energy demand are needed and for some devices also additional data is needed e.g. for the dishwater, you can define if it has a DHW connection or a cold water connection.

If you dont know the inner sources of the building yet, you can click on the standart dataset and WUFI will put in the standart amount of devices in a common household.

Non-residential building

Utilization pattern

Utilization pattern

The mandatory data for utilization patterns is given over the columns of the table. The additional data is useful, depending on where the pattern is attached.

Occupancy

Occupancy

Here you can define how many occupants your building has as well as additional humidity sources. When it comes to the activity of the occupants, WUFI can differ between children, sitting adults and standing adults. It is also possible to define the pattern for these people as well the quantity of people following this pattern.
The additional data section contains a value about additional heat losses through evaporation and toilet settings.
WUFI can use default values for a school if you are building one.