Passive:Dynamic Simulation: Unterschied zwischen den Versionen
Aus Wufiwiki
Zur Navigation springenZur Suche springen
SebSta (Diskussion | Beiträge) Keine Bearbeitungszusammenfassung |
SebSta (Diskussion | Beiträge) |
||
Zeile 1: | Zeile 1: | ||
== Switch to dynamic Mode == | == Switch to dynamic Mode == | ||
=== Set Boundary Conditions from Passive House === | === Set Boundary Conditions from Passive House === | ||
[[Bild:Passive-resultbox_error.png|left]] | [[Bild:Passive-resultbox_error.png|left]] | ||
Certain input parameters can be taken over from WUFI®Passive to WUFI®Plus. To simplify this step new a button "Set Boundary Conditions from Passive House" has been introduced. This option will set reasonable values for the dynamic simulation mode for better comparison of the results. | Certain input parameters can be taken over from WUFI®Passive to WUFI®Plus. To simplify this step new a button "Set Boundary Conditions from Passive House" has been introduced. This option will set reasonable values for the dynamic simulation mode for better comparison of the results. | ||
<br> | |||
<br> | |||
Setpoints for WUFI®Plus in detail: | |||
<br> Temperature: Design Minimal Temperature = indoor temperature, Design Maximal Temperature = overheating temperature, | |||
<br> Ground temperature: New optional ground climate added with Relative Humidity = 99 constant, Temperature = sin curve with min/max values and phase shift from WUFI®Passive calculation | |||
<br> Ground temperature: | |||
<br style="clear:both" /> | <br style="clear:both" /> |
Version vom 17. Juli 2013, 10:50 Uhr
Switch to dynamic Mode
Set Boundary Conditions from Passive House
Certain input parameters can be taken over from WUFI®Passive to WUFI®Plus. To simplify this step new a button "Set Boundary Conditions from Passive House" has been introduced. This option will set reasonable values for the dynamic simulation mode for better comparison of the results.
Setpoints for WUFI®Plus in detail:
Temperature: Design Minimal Temperature = indoor temperature, Design Maximal Temperature = overheating temperature,
Ground temperature: New optional ground climate added with Relative Humidity = 99 constant, Temperature = sin curve with min/max values and phase shift from WUFI®Passive calculation
Ground temperature: