Passive:Dynamic Simulation: Unterschied zwischen den Versionen
Aus Wufiwiki
Zur Navigation springenZur Suche springen
SebSta (Diskussion | Beiträge) |
SebSta (Diskussion | Beiträge) |
||
Zeile 2: | Zeile 2: | ||
=== Set Boundary Conditions from Passive House === | === Set Boundary Conditions from Passive House === | ||
[[Bild:Passive-resultbox_error.png|left]] | [[Bild:Passive-resultbox_error.png|left]] | ||
Certain input parameters can be taken over from WUFI®Passive to WUFI®Plus. To simplify this step new a button "Set Boundary Conditions from Passive House" has been introduced. This option will set reasonable values for the dynamic simulation mode for better comparison of the results. | Certain input parameters can be taken over from WUFI®Passive to WUFI®Plus. To simplify this step new a button "Set Boundary Conditions from Passive House" has been introduced. This option will set reasonable values for the dynamic simulation mode for better comparison of the results. |
Version vom 17. Juli 2013, 14:00 Uhr
Switch to dynamic Mode
Set Boundary Conditions from Passive House
Certain input parameters can be taken over from WUFI®Passive to WUFI®Plus. To simplify this step new a button "Set Boundary Conditions from Passive House" has been introduced. This option will set reasonable values for the dynamic simulation mode for better comparison of the results.
Setpoints for WUFI®Plus in detail:
Temperature: Design Minimal Temperature = indoor temperature, Design Maximal Temperature = overheating temperature,
Ground temperature: New optional ground climate added with Relative Humidity = 99 constant, Temperature = sin curve with min/max values and phase shift from WUFI®Passive calculation
Internal loads: