WUFI® calculates the ground temperature depending on the different types of foundations (Reference:EN ISO 13370). Therefor four different types are avaible. You also have the option to let WUFI detect the given type by itself or input an own ground temperature measurement. This measurement must be given in climate file and will be shown in the fourth row of the [[Passive2:Dialog_Climate#Climate|Climate tab]].<br>
WUFI® calculates the ground temperature depending on the different types of foundations (Reference:EN ISO 13370). Therefor four different types are avaible. You also have the option to let WUFI detect the given type by itself or input an own ground temperature measurement. This measurement must be given in climate file and will be shown in the fourth row of the [[Passive2:Dialog_Climate#Climate|Climate tab]].<br>
[[Bild:Passive-phcase_foundint_scope.png|Foundation scope]]<br style="clear:both" />
[[Bild:Passive-phcase_foundint_scope.png|Foundation scope]]
=== Parameters ===
=== Parameters ===
Depending on the type of foundation, different values are needed for WUFI. You have the option to either specify them yourself or let WUFI detect them automatically.
Depending on the type of foundation, different values are needed for WUFI. You have the option to either specify them yourself or let WUFI detect them automatically.<br style="clear:both" />

Version vom 20. Juni 2013, 12:19 Uhr

General

Parameters

General

In this section you can select your building category Passive-phcase residentscope.png
and the occupancy type depending on which category you want to calculate. There are different pick options, depending if you want to simulate a residential building or a non-residential one.

Residential
Non-residential




This choice has influence on the predefined internal loads.

The indoor temperature defines the mean indoor temperature during the heating period. The tooltip recommends 20°C (68°F) for residential buildings and for non-residential buildings, the calculation method is described in EN 13790.

The internal can either be calculated depending on the equipment or a predefined value can be used.

The occupancy setting method has two choices, design and verification. Design uses the occupant quantity from inner loads and is the default value for non-residential buildings and can not be changed there. Verification depends on the treated floor area when calculating the occupant quantity.

The number of units represents the amount of dwellings in the building.

Zones

Additional zones can be implemented here, to calculate different buildings at the same time. They can also be named here.

Additional data

Required data

Additional data

The first two values describe the lower limit of indoor temperature achieved by ventilation and the maximum indoor temperature during summer.

Maybe someone else, can explain the details about air exchanges.

For the building wind exposure, WUFI has some predefined values, which can be chosen at den "Building wind exposure" scope. If you do have different values in the following three columns, you can use the "User defined" tab and input your values yourself.
Scope wind exposure

Optional Data

These values can be given, if available but are not necessary because WUFI does caluclate them itself.

Calculator humidity ratio

This is a little tool to calculate the maximum water vapour content in the air, depending on the air temperature and the dew point. You can then set the calculated maximum humidity ratio into the column in the table above.

Foundation interface

Foundation interface

WUFI® calculates the ground temperature depending on the different types of foundations (Reference:EN ISO 13370). Therefor four different types are avaible. You also have the option to let WUFI detect the given type by itself or input an own ground temperature measurement. This measurement must be given in climate file and will be shown in the fourth row of the Climate tab.
Foundation scope

Parameters

Depending on the type of foundation, different values are needed for WUFI. You have the option to either specify them yourself or let WUFI detect them automatically.