Passive:Verification: Unterschied zwischen den Versionen

Aus Wufiwiki
Zur Navigation springenZur Suche springen
Zeile 26: Zeile 26:
[[Bild:Passive-verification_heat_flow.png|right|thumb]]
[[Bild:Passive-verification_heat_flow.png|right|thumb]]
Heat gains and losses are divided on different causes. <br>
Heat gains and losses are divided on different causes. <br>
Heat gains are seperated into solar gains, [[Passive2:Inner_Loads|inner sources]], thermal bridges and mechanical heating.<br>
Heat gains are seperated into solar gains, [[Passive2:Inner_Loads|inner sources]], thermal bridges and mechanical heating.<br> <br>
Heat losses are seperated into windows&doors, the building envelope and natural and mechanical ventilation.<br>
Heat losses are seperated into windows&doors, the building envelope and natural and mechanical ventilation.<br> <br>
Both statistics are displayed in a pie chart.<br style="clear:both" />
Both statistics are displayed in a pie chart.<br style="clear:both" />



Version vom 27. Juni 2013, 14:12 Uhr

Results of Passive House Verification

This page shows the different subpoint of the output of the Passive House Verification. To each subpoint there will be a short description of the output parameters as well as a screenshot.

Building Information

The first section summarizes some general information about the building itself.


Passivehouse requirements

The primary passive house requirements depend mostly on needed energy, mostly in the form of cooling and heating as well as primary energy demand. All values are given in a specific value (per square meter/feet) and in total. Heating and cooling demand also provide a peak value(month).

Secondary Passivehouse Requirements

The scondary requirements consist of the HRV efficiency and a percentage chance of overheating of the building. Depending on the numbers WUFI®Passive will give recommendation if a seperate cooling system is needed or not.

Building Elements

The building elements describes the influences of windows, HVAC systems and electric devices on the energy demand.

Windows

The graphic shows the heat losses and gains of solar radiation through windows depending on the orientation. Also average values over all windows are given together with the total glazing area.

HVAC

The energy demand of all HVAC devices is listed here.

Electricity

The energy demand of all other electric devices is listed here.

Heat Flow

Heat gains and losses are divided on different causes.
Heat gains are seperated into solar gains, inner sources, thermal bridges and mechanical heating.

Heat losses are seperated into windows&doors, the building envelope and natural and mechanical ventilation.

Both statistics are displayed in a pie chart.

Climate


Calculation Parameters


Annual Heat/Cooling Demand


Heating/Cooling Load


Areas


Thermal Brigdes


Windows

A new screenshot is needed here.

Summary Building Envelope


HVAC Systems


Ventilation


Electricity Demand - Auxiliary Electricity


Electricity Demand Residential Building


Internal Heat Gains


DHW and Distribution