Passive2:Dialog Climate: Unterschied zwischen den Versionen
SebSta (Diskussion | Beiträge) |
SebSta (Diskussion | Beiträge) |
||
Zeile 11: | Zeile 11: | ||
== Climate == | == Climate == | ||
[[Bild:Passive-case1_climate.png|thumb|right|Climate]] | [[Bild:Passive-case1_climate.png|thumb|right|Climate]] | ||
=== Temperature === | === Temperature === | ||
The first section shows the mean temperature of each month, which is also shown in the left graphic. On the very right the extreme weather conditions are shown, which are needed to calculate the heating load of the building.<br> | The first section shows the mean temperature of each month, which is also shown in the left graphic. On the very right the extreme weather conditions are shown, which are needed to calculate the heating load of the building.<br> |
Version vom 23. Juli 2013, 10:19 Uhr
Unlike WUFI®Plus, WUFI®Passive does not hourly data for calculation.
Localization
In the localization tab you can select your climate file. By clicking on the selection scope, you can click on "user defined" and browse your own climate file. As WUFI®Passive does not need hourly data, it does need a different kind of climate files. It can only read .txt and .xls files with a special formation. This formation can be generated with meteonorm. See pictures below or this movie for examples.
Climate
Temperature
The first section shows the mean temperature of each month, which is also shown in the left graphic. On the very right the extreme weather conditions are shown, which are needed to calculate the heating load of the building.
Solar radiation
The second section contains the mean monthly solar irradiation, seperated into the four cardinal points. The right picture also shows the course of the graph and again on the very right, there are extreme weather conditions.
Primary energy/CO2-factor
In this tab, you can see and set the primary energy factor (PEF) and the CO2-emission factor (CO2EF).
The PEF multiplies with the energy demand and varies depending on the chosen material, because the PEF is influenced by both the production process and the transportation of the energy source.
The CO2EF converts the energy demand into an equivalent amount of CO2. These two factors are important when looking into the sustainability of the passive house.
Though differences are minor, WUFI knows 3 different standarts regarding the values of this table. If you do have different ones, you can set your own table in the "user defined" section.