Passive2:PH case
General
Parameters
In this section the building category is chosen
and the occupancy type depending on which category is to calculate. There are different pick options, depending if the building is a resdiential one or not.
This choice has influence on the predefined internal loads.
The indoor temperature defines the mean indoor temperature during the heating period. The tooltip recommends 20°C (68°F) for residential buildings and for non-residential buildings, the calculation method is described in EN 13790.
The internal can either be calculated depending on the equipment or a predefined value can be used.
The occupancy setting method has two choices, design and verification. Design uses the occupant quantity from inner loads and is the default value for non-residential buildings and can not be changed there. Verification depends on the treated floor area when calculating the occupant quantity.
The number of units represents the amount of dwellings in the building.
Zones
Additional zones can be implemented here, to calculate different buildings at the same time. They can also be named here.
Additional data
Required data
The first two values describe the lower limit of indoor temperature achieved by ventilation and the maximum indoor temperature during summer.
Maybe someone else, can explain the details about air exchanges.
For the building wind exposure, WUFI has predefined values, which can be chosen at den "Building wind exposure" scope. If you do have different values in the following three columns, you can use the "User defined" tab and input your values yourself.
Optional Data
These values can be given, if available but are not necessary because WUFI does caluclate them itself.
Calculator humidity ratio
This is a little tool to calculate the maximum water vapour content in the air, depending on the air temperature and the dew point. You can then set the calculated maximum humidity ratio into the column in the table above.
Foundation interface
WUFI® calculates the ground temperature depending on the different types of foundations (Reference:EN ISO 13370). Therefor four different types are avaible. You also have the option to let WUFI detect the given type by itself or input an own ground temperature measurement. This measurement must be given in climate file and will be shown in the fourth row of the Climate tab.
Parameters
Depending on the type of foundation, different values are needed for WUFI. You have the option to either specify them yourself or let WUFI detect them automatically.